INTERNALLY HEATED WEIGHED REACTOR THERMOBALANCE FOR GAS-SOLID REACTION STUDIES.

Michael H. Treptau, Dennis J. Miller

Research output: Research - peer-reviewArticle

  • 1 Citations

Abstract

A novel thermobalance apparatus is described which alleviates some problems traditionally associated with thermogravimetric reaction studies. The new design provides direct measurement of sample temperature, elimination of external mass-transfer resistances via gas flow directly through the sample bed, and added safety using a cold-wall vessel design. The sensitivity of the balance is approximately plus or minus 10 mg for a 2-g carbon sample. The apparatus consists of a pressure vessel, a counterweighted balance arm, and a top-loading electronic balance. Results from gasification with CO//2 and O//2 show that the balance adequately measures sample weight during reaction.

LanguageEnglish (US)
Pages2007-2011
Number of pages5
JournalIndustrial and Engineering Chemistry Research
Volume26
Issue number10
StatePublished - Oct 1987

Profile

vessel
gas
reactor
Gases
gas flow
mass transfer
safety
carbon
temperature
cold
electronics
gasification
Carbon Monoxide
Pressure vessels
Gasification
Flow of gases
Carbon
Mass transfer
Temperature

ASJC Scopus subject areas

  • Chemical Engineering (miscellaneous)
  • Environmental Science(all)
  • Polymers and Plastics

Cite this

INTERNALLY HEATED WEIGHED REACTOR THERMOBALANCE FOR GAS-SOLID REACTION STUDIES. / Treptau, Michael H.; Miller, Dennis J.

In: Industrial and Engineering Chemistry Research, Vol. 26, No. 10, 10.1987, p. 2007-2011.

Research output: Research - peer-reviewArticle

@article{3de7db9b46e9461ebbec6995987c2345,
title = "INTERNALLY HEATED WEIGHED REACTOR THERMOBALANCE FOR GAS-SOLID REACTION STUDIES.",
abstract = "A novel thermobalance apparatus is described which alleviates some problems traditionally associated with thermogravimetric reaction studies. The new design provides direct measurement of sample temperature, elimination of external mass-transfer resistances via gas flow directly through the sample bed, and added safety using a cold-wall vessel design. The sensitivity of the balance is approximately plus or minus 10 mg for a 2-g carbon sample. The apparatus consists of a pressure vessel, a counterweighted balance arm, and a top-loading electronic balance. Results from gasification with CO//2 and O//2 show that the balance adequately measures sample weight during reaction.",
author = "Treptau, {Michael H.} and Miller, {Dennis J.}",
year = "1987",
month = "10",
volume = "26",
pages = "2007--2011",
journal = "Industrial & Engineering Chemistry Product Research and Development",
issn = "0888-5885",
publisher = "American Chemical Society",
number = "10",

}

TY - JOUR

T1 - INTERNALLY HEATED WEIGHED REACTOR THERMOBALANCE FOR GAS-SOLID REACTION STUDIES.

AU - Treptau,Michael H.

AU - Miller,Dennis J.

PY - 1987/10

Y1 - 1987/10

N2 - A novel thermobalance apparatus is described which alleviates some problems traditionally associated with thermogravimetric reaction studies. The new design provides direct measurement of sample temperature, elimination of external mass-transfer resistances via gas flow directly through the sample bed, and added safety using a cold-wall vessel design. The sensitivity of the balance is approximately plus or minus 10 mg for a 2-g carbon sample. The apparatus consists of a pressure vessel, a counterweighted balance arm, and a top-loading electronic balance. Results from gasification with CO//2 and O//2 show that the balance adequately measures sample weight during reaction.

AB - A novel thermobalance apparatus is described which alleviates some problems traditionally associated with thermogravimetric reaction studies. The new design provides direct measurement of sample temperature, elimination of external mass-transfer resistances via gas flow directly through the sample bed, and added safety using a cold-wall vessel design. The sensitivity of the balance is approximately plus or minus 10 mg for a 2-g carbon sample. The apparatus consists of a pressure vessel, a counterweighted balance arm, and a top-loading electronic balance. Results from gasification with CO//2 and O//2 show that the balance adequately measures sample weight during reaction.

UR - http://www.scopus.com/inward/record.url?scp=0023434349&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023434349&partnerID=8YFLogxK

M3 - Article

VL - 26

SP - 2007

EP - 2011

JO - Industrial & Engineering Chemistry Product Research and Development

T2 - Industrial & Engineering Chemistry Product Research and Development

JF - Industrial & Engineering Chemistry Product Research and Development

SN - 0888-5885

IS - 10

ER -